翻訳と辞書
Words near each other
・ Inductive amplifier
・ Inductive Automation
・ Inductive bias
・ Inductive charging
・ Inductive cleavage
・ Inductive coupling
・ Inductive data type
・ Inductive dimension
・ Inductive discharge ignition
・ Inductive effect
・ Inductive functional programming
・ Inductive logic programming
・ Inductive output tube
・ Inductive probability
・ Inductive programming
Inductive pump
・ Inductive reasoning
・ Inductive reasoning aptitude
・ Inductive sensor
・ Inductive set
・ Inductive transfer
・ Inductive type
・ Inductively coupled plasma
・ Inductively coupled plasma atomic emission spectroscopy
・ Inductively coupled plasma mass spectrometry
・ Inductivism
・ Inductor
・ Inductrack
・ Induk University
・ Indukantha ghritha


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Inductive pump : ウィキペディア英語版
Inductive pump

An Inductive pump is a magnetically regulated positive displacement pump used to pump liquids and gases. It is capable of handling many corrosive chemicals as well as solvents and gases. It is characterized by a single piston that reciprocates within a magnetic field and therefore doesn’t require a dynamic seal to link the piston to an outside mechanical power source. Check valves are placed at both ends of the piston housing allowing the simultaneous suctioning and pumping that reverses with each stroke. This is known to reduce pulsations especially at higher flow rates. The piston and housing are constructed of materials that are inert to many liquids and gasses. Because the piston and housing are non-plastic materials the positive displacement chamber does not change in dimension from flexing and distortion thus allowing inductive pumps to remain very accurate with no significant changes over time. Inductive pumps are extremely accurate as each stroke contains the same volume created by a solid piston inside a solid chamber. The number of strokes can be counted or timed to determine the total volume delivered. They can be used in sterile and controlled environments as they will not leak to the outside of the housing even if the piston has experienced wear.
==Efficiency==

Inductive pumps are considered highly accurate and energy efficient. Inductive pumps use two primary parameters to control flow, they are Rate and Dwell. Rate is used to determine the number of strokes per second or in any given time interval. Dwell is used to control the length of time the energizing coil remains on during the Rate cycle. Essentially if the piston has completed its stroke and is waiting for the reverse cycle to occur, there is no need to continue energizing the coil as most of this energy will be converted to heat as no more work is being done by the piston. The Dwell setting allows adjustment of this ON time during the rate cycle. Also the Dwell setting allows for a true pressure control parameter for the pump. By reducing the Dwell time even further one can reduce the total energy applied to the piston during the pumping cycle. This can reduce the maximum output pressure during pumping. This differs from many other pumps as they commonly reduce flow to reduce pressure in a given circumstance, however if an occlusion occurs to the output channel other pumps tend to build up to their maximum pressure until they either burst the tubing or damage their internal mechanism. Inductive pumps can be shut off at the outlet and will not exceed the pressure they are set at. Pumping against a close output does not cause damage to the pump.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)